JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD
- JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG are communication and signaling cables with copper conductors, ceramic-forming silicone rubber insulation and a sheath made of a halogen-free composition with low gas and smoke emission, twisted in pairs.
- JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD are communication and signaling cables with copper conductors, ceramic-forming silicone rubber insulation and a sheath made of a halogen-free composition with low gas and smoke emission, of bundle twisting.
- They are designed for stationary installation inside buildings and premises, for transmission of low-power electrical signals in signaling, communication and telecommunication systems, at facilities with increased fire safety requirements, for operation at alternating voltages of up to 300 V.
- They are used as a control and connecting cable in control-measuring instruments, industrial electronics, computers, office equipment, information systems, for the transmission of audio frequencies, data and electronic information, as well as in fire alarm systems.
- They remain operational in fire, do not spread combustion, have a low level of smoke emission, and do not emit corrosive and toxic gases. They are used where, in the event of a fire, it is necessary to ensure increased safety of people and protection of electronic equipment.
operation: from -30°C to +50°C
JE – cables for data and signal transmission;
H – insulation does not contain halogens (ceramic-forming silicone rubber);
H – the sheath does not contain halogens (halogen-free composition with low gas and smoke emission);
FE180 – cables for their ability to maintain the integrity of the circuits under conditions of exposure to a flame whose temperature is not less than 750 ° С, comply with FE180 (4.8 of the National Standards of Ukraine 4809);
E30 – cables according to their ability to maintain the integrity of electrical circuits under standard temperature conditions correspond to Ek30 (4.7 DSTU 4809);
E90 – cables according to their ability to maintain the integrity of electrical circuits under standard temperature conditions correspond to Ek90 (4.7 of the National Standards of Ukraine 4809);
LG – twisted pair cables;
BD – bunched cables.
Conductors: copper round single-wire |
Insulation: insulation made of ceramic-forming silicone rubber, sheath is a halogen-free composition with low gas and smoke emission |
Armor: no |
Number of pairs (bundles) | Nominal diameter of conductors, mm |
---|---|
1 – 32 | 0,4; 0,5; 0,6; 0,8; 1,05; 1,13; 1,38; 1,78 |
- The National Standards of Ukraine 4809:2007
- JE-HH FE180/E30…LG, JE-HH FE180/E30… BD - PB 123122288
- JE-HH FE180/E90… LG, JE-HH FE180/E90… BD - PB 123122588
JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD are communication and signaling cables with copper conductors, insulated with ceramic forming silicone rubber and a sheath of a halogen-free composition with low gas and smoke emission.
Applicability scope
JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD cables are analogous to JE-H(St)H FE180/E30 …LG (BD) and JE-H(St)H FE180/E90 …LG(BD) shielded cables. They are also intended for stationary installation inside premises and buildings and are used to transmit low-power electrical signals in signaling, communication and telecommunication systems, at facilities with increased fire safety requirements, for operation at alternating voltages of up to 300 V.
They are used as a control or connection cable for the data transmission, in industrial control-measuring equipment, office devices, fire alarm systems and intercom systems.
Due to the special design, the cables do not spread combustion and have a low level of smoke emission, and the absence of halogens and, accordingly, low toxic combustion products, allow the use of cables of this brand in social institutions: schools, hospitals, shopping and entertainment complexes, the subway, as well as in residential buildings. In the event of a fire, such cables ensure the operability of the equipment for a certain period of time and allow a complete evacuation of people.
Cables marked E30: JE-HH FE180/E30 …LG (BD) remain operational under fire for 30 minutes, and products marked E90: JE-HH FE180/E90 …LG (BD) can function 90 minutes in case of fire.
Design
The JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD are designed using round copper single-wire conductors. Insulated conductors are twisted together. The LG marking indicates a pair type of stranding of conductors, and the letters BD indicate bundled cables. The number of pairs (bundles) varies from 1 to 32, and the diameter of the conductors is from 0.4 to 1.78 mm.
Insulation of JE-HH FE180/E30 …LG (BD), JE-HH FE180/E90 …LG (BD) is made of ceramic-forming silicone rubber, which emits a minimum amount of substances harmful to humans when exposed to fire. The cable sheath is made of a halogen-free composition, which ensures a significant reduction in the level of gas and smoke emission and the safety of cables for the environment.
You can get more detailed information on the design of cables from the experts of the sales department of EUROPAN LLC.
Operation
JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD cables are designed for operation at ambient temperatures from -30°C to +50°С and maximum air humidity 98% at temperatures of up to +35°С.
Laying without preheating is allowed at a temperature not lower than -15°C.
The minimum bending radius during installation must be at least 15 outer diameters.
The service life of the cables is 15 years. The guaranteed service life is 6 months.
The website of EUROPAN LLC presents a wide selection of cables and wires for various purposes. Cables for connecting solar panels, communication and signaling, telephone wires and wire radio broadcasting, fire-resistant, low-smoke and non-toxic halogen-free cables – this is not a complete list of products presented on our website. All our products are certified and meet the highest quality standards. You can select and order a cable of the required label size at wholesale prices and with fast delivery to any corner of Ukraine and the CIS country on the website or by phone.
Select rated voltage, kV
Number of pairs and nominal diameter of conductors, mm |
Nominal outer diameter, mm |
Estimated weight of 1 km of cable, kg |
1х2х0,4 |
4,8 |
28 |
2х2х0,4 |
6,6 |
45 |
3х2х0,4 |
7,0 |
54 |
4х2х0,4 |
7,6 |
65 |
5х2х0,4 |
8,2 |
76 |
6х2х0,4 |
8,9 |
87 |
8х2х0,4 |
9,6 |
105 |
10х2х0,4 |
11,4 |
135 |
12х2х0,4 |
11,8 |
152 |
16х2х0,4 |
13,0 |
189 |
20х2х0,4 |
14,6 |
234 |
24х2х0,4 |
16,2 |
274 |
30х2х0,4 |
17,2 |
325 |
32х2х0,4 |
17,8 |
344 |
1х2х0,5 |
5,0 |
30 |
2х2х0,5 |
7,0 |
50 |
3х2х0,5 |
7,3 |
62 |
4х2х0,5 |
8,0 |
74 |
5х2х0,5 |
8,7 |
87 |
6х2х0,5 |
9,4 |
101 |
8х2х0,5 |
10,4 |
128 |
10х2х0,5 |
12,1 |
157 |
12х2х0,5 |
12,5 |
178 |
16х2х0,5 |
13,8 |
223 |
20х2х0,5 |
15,5 |
276 |
24х2х0,5 |
17,2 |
325 |
30х2х0,5 |
18,2 |
387 |
32х2х0,5 |
19,1 |
420 |
1х2х0,6 |
5,6 |
37 |
2х2х0,6 |
8,0 |
63 |
3х2х0,6 |
8,4 |
79 |
4х2х0,6 |
9,2 |
96 |
5х2х0,6 |
10,0 |
114 |
6х2х0,6 |
11,1 |
137 |
8х2х0,6 |
12,0 |
169 |
10х2х0,6 |
14,1 |
207 |
12х2х0,6 |
14,7 |
244 |
16х2х0,6 |
16,3 |
306 |
20х2х0,6 |
18,1 |
370 |
24х2х0,6 |
20,4 |
446 |
30х2х0,6 |
21,6 |
533 |
32х2х0,6 |
22,4 |
566 |
1х2х0,8 |
6,2 |
48 |
2х2х0,8 |
8,8 |
82 |
3х2х0,8 |
9,3 |
103 |
4х2х0,8 |
10,2 |
127 |
5х2х0,8 |
11,1 |
151 |
6х2х0,8 |
12,5 |
188 |
8х2х0,8 |
13,5 |
232 |
10х2х0,8 |
15,8 |
284 |
12х2х0,8 |
16,3 |
325 |
16х2х0,8 |
18,3 |
420 |
20х2х0,8 |
20,2 |
509 |
24х2х0,8 |
22,5 |
599 |
30х2х0,8 |
23,9 |
720 |
32х2х0,8 |
24,8 |
764 |
1х2х1,05 |
7,1 |
63 |
2х2х1,05 |
10,3 |
112 |
3х2х1,05 |
10,9 |
145 |
4х2х1,05 |
11,9 |
180 |
5х2х1,05 |
13,1 |
216 |
6х2х1,05 |
14,7 |
267 |
8х2х1,05 |
15,9 |
333 |
10х2х1,05 |
18,7 |
411 |
12х2х1,05 |
19,3 |
473 |
16х2х1,05 |
21,5 |
605 |
20х2х1,05 |
23,9 |
738 |
24х2х1,05 |
27,0 |
887 |
30х2х1,05 |
28,6 |
1074 |
32х2х1,05 |
29,8 |
1141 |
1х2х1,13 |
7,3 |
67 |
2х2х1,13 |
10,5 |
120 |
3х2х1,13 |
11,2 |
155 |
4х2х1,13 |
12,2 |
194 |
5х2х1,13 |
13,8 |
247 |
6х2х1,13 |
15,1 |
288 |
8х2х1,13 |
16,3 |
361 |
10х2х1,13 |
19,2 |
446 |
12х2х1,13 |
19,9 |
514 |
16х2х1,13 |
22,1 |
659 |
20х2х1,13 |
24,8 |
817 |
24х2х1,13 |
27,7 |
968 |
30х2х1,13 |
29,4 |
1173 |
32х2х1,13 |
30,8 |
1263 |
1х2х1,38 |
8,0 |
85 |
2х2х1,38 |
11,6 |
152 |
3х2х1,38 |
12,2 |
200 |
4х2х1,38 |
13,4 |
250 |
5х2х1,38 |
14,8 |
302 |
6х2х1,38 |
16,5 |
371 |
8х2х1,38 |
17,9 |
467 |
10х2х1,38 |
21,1 |
577 |
12х2х1,38 |
21,8 |
668 |
16х2х1,38 |
24,3 |
859 |
20х2х1,38 |
27,0 |
1052 |
24х2х1,38 |
30,4 |
1264 |
30х2х1,38 |
32,3 |
1537 |
32х2х1,38 |
33,6 |
1634 |
1х2х1,78 |
9,2 |
116 |
2х2х1,78 |
13,5 |
214 |
3х2х1,78 |
14,4 |
287 |
4х2х1,78 |
16,2 |
380 |
5х2х1,78 |
17,8 |
460 |
6х2х1,78 |
19,5 |
540 |
8х2х1,78 |
21,1 |
687 |
10х2х1,78 |
25,0 |
851 |
12х2х1,78 |
25,9 |
992 |
16х2х1,78 |
29,1 |
1300 |
20х2х1,78 |
32,4 |
1597 |
24х2х1,78 |
36,5 |
1917 |
30х2х1,78 |
38,8 |
2342 |
32х2х1,78 |
40,4 |
2490 |
Select rated voltage, kV
Number of pairs and nominal diameter of conductors, mm |
Nominal outer diameter, mm |
Estimated weight of 1 km of cable, kg |
1х2х0,4 |
4,8 |
28 |
2х2х0,4 |
6,6 |
45 |
3х2х0,4 |
7,0 |
54 |
4х2х0,4 |
7,6 |
65 |
5х2х0,4 |
8,2 |
76 |
6х2х0,4 |
8,9 |
88 |
8х2х0,4 |
9,6 |
106 |
10х2х0,4 |
11,4 |
136 |
12х2х0,4 |
11,8 |
153 |
16х2х0,4 |
13,0 |
191 |
20х2х0,4 |
14,6 |
236 |
24х2х0,4 |
16,2 |
277 |
30х2х0,4 |
17,2 |
328 |
32х2х0,4 |
17,8 |
347 |
1х2х0,5 |
5,0 |
31 |
2х2х0,5 |
7,0 |
51 |
3х2х0,5 |
7,3 |
62 |
4х2х0,5 |
8,0 |
75 |
5х2х0,5 |
8,7 |
88 |
6х2х0,5 |
9,4 |
101 |
8х2х0,5 |
10,4 |
129 |
10х2х0,5 |
12,1 |
158 |
12х2х0,5 |
12,5 |
179 |
16х2х0,5 |
13,8 |
225 |
20х2х0,5 |
15,5 |
279 |
24х2х0,5 |
17,2 |
327 |
30х2х0,5 |
18,2 |
390 |
32х2х0,5 |
19,1 |
424 |
1х2х0,6 |
5,6 |
38 |
2х2х0,6 |
8,0 |
64 |
3х2х0,6 |
8,4 |
79 |
4х2х0,6 |
9,2 |
97 |
5х2х0,6 |
10,0 |
115 |
6х2х0,6 |
11,1 |
138 |
8х2х0,6 |
12,0 |
170 |
10х2х0,6 |
14,1 |
209 |
12х2х0,6 |
14,7 |
246 |
16х2х0,6 |
16,3 |
309 |
20х2х0,6 |
18,1 |
374 |
24х2х0,6 |
20,4 |
451 |
30х2х0,6 |
21,6 |
539 |
32х2х0,6 |
22,4 |
571 |
1х2х0,8 |
6,2 |
48 |
2х2х0,8 |
8,8 |
82 |
3х2х0,8 |
9,3 |
104 |
4х2х0,8 |
10,2 |
128 |
5х2х0,8 |
11,1 |
152 |
6х2х0,8 |
12,5 |
189 |
8х2х0,8 |
13,5 |
233 |
10х2х0,8 |
15,8 |
286 |
12х2х0,8 |
16,3 |
327 |
16х2х0,8 |
18,3 |
424 |
20х2х0,8 |
20,2 |
513 |
24х2х0,8 |
22,5 |
604 |
30х2х0,8 |
23,9 |
726 |
32х2х0,8 |
24,8 |
771 |
1х2х1,05 |
7,1 |
64 |
2х2х1,05 |
10,3 |
113 |
3х2х1,05 |
10,9 |
145 |
4х2х1,05 |
11,9 |
181 |
5х2х1,05 |
13,1 |
217 |
6х2х1,05 |
14,7 |
269 |
8х2х1,05 |
15,9 |
336 |
10х2х1,05 |
18,7 |
414 |
12х2х1,05 |
19,3 |
477 |
16х2х1,05 |
21,5 |
609 |
20х2х1,05 |
23,9 |
744 |
24х2х1,05 |
27,0 |
894 |
30х2х1,05 |
28,6 |
1083 |
32х2х1,05 |
29,8 |
1150 |
1х2х1,13 |
7,3 |
68 |
2х2х1,13 |
10,5 |
120 |
3х2х1,13 |
11,2 |
156 |
4х2х1,13 |
12,2 |
195 |
5х2х1,13 |
13,8 |
249 |
6х2х1,13 |
15,1 |
290 |
8х2х1,13 |
16,3 |
364 |
10х2х1,13 |
19,2 |
449 |
12х2х1,13 |
19,9 |
518 |
16х2х1,13 |
22,1 |
664 |
20х2х1,13 |
24,8 |
824 |
24х2х1,13 |
27,7 |
975 |
30х2х1,13 |
29,4 |
1183 |
32х2х1,13 |
30,8 |
1273 |
1х2х1,38 |
8,0 |
85 |
2х2х1,38 |
11,6 |
153 |
3х2х1,38 |
12,2 |
201 |
4х2х1,38 |
13,4 |
252 |
5х2х1,38 |
14,8 |
304 |
6х2х1,38 |
16,5 |
373 |
8х2х1,38 |
17,9 |
470 |
10х2х1,38 |
21,1 |
581 |
12х2х1,38 |
21,8 |
673 |
16х2х1,38 |
24,3 |
865 |
20х2х1,38 |
27,0 |
1059 |
24х2х1,38 |
30,4 |
1273 |
30х2х1,38 |
32,3 |
1548 |
32х2х1,38 |
33,6 |
1646 |
1х2х1,78 |
9,2 |
117 |
2х2х1,78 |
13,5 |
215 |
3х2х1,78 |
14,4 |
288 |
4х2х1,78 |
16,2 |
382 |
5х2х1,78 |
17,8 |
462 |
6х2х1,78 |
19,5 |
543 |
8х2х1,78 |
21,1 |
691 |
10х2х1,78 |
25,0 |
856 |
12х2х1,78 |
25,9 |
998 |
16х2х1,78 |
29,1 |
1308 |
20х2х1,78 |
32,4 |
1607 |
24х2х1,78 |
36,5 |
1929 |
30х2х1,78 |
38,8 |
2357 |
32х2х1,78 |
40,4 |
2507 |