JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD

Technical Conditions U 27.3-39543889-014:2021
  • JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG are communication and signaling cables with copper conductors, ceramic-forming silicone rubber insulation and a sheath made of a halogen-free composition with low gas and smoke emission, twisted in pairs.
  • JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD are communication and signaling cables with copper conductors, ceramic-forming silicone rubber insulation and a sheath made of a halogen-free composition with low gas and smoke emission, of bundle twisting.
  • They are designed for stationary installation inside buildings and premises, for transmission of low-power electrical signals in signaling, communication and telecommunication systems, at facilities with increased fire safety requirements, for operation at alternating voltages of up to 300 V.
  • They are used as a control and connecting cable in control-measuring instruments, industrial electronics, computers, office equipment, information systems, for the transmission of audio frequencies, data and electronic information, as well as in fire alarm systems.
  • They remain operational in fire, do not spread combustion, have a low level of smoke emission, and do not emit corrosive and toxic gases. They are used where, in the event of a fire, it is necessary to ensure increased safety of people and protection of electronic equipment.
Minimum service life is 15 years
Guaranteed service life is 6 months
Minimum bending radius 15 x outer diameter
Temperature range installation: not lower than -15°C
operation: from -30°C to +50°C
Interpretation of cables JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD

JE – cables for data and signal transmission;

H – insulation does not contain halogens (ceramic-forming silicone rubber);

H – the sheath does not contain halogens (halogen-free composition with low gas and smoke emission);

FE180 – cables for their ability to maintain the integrity of the circuits under conditions of exposure to a flame whose temperature is not less than 750 ° С, comply with FE180 (4.8 of the National Standards of Ukraine 4809);

E30 – cables according to their ability to maintain the integrity of electrical circuits under standard temperature conditions correspond to Ek30 (4.7 DSTU 4809);

E90 – cables according to their ability to maintain the integrity of electrical circuits under standard temperature conditions correspond to Ek90 (4.7 of the National Standards of Ukraine 4809);

LG – twisted pair cables;

BD – bunched cables.

Design
Conductors: copper round single-wire
Insulation: insulation made of ceramic-forming silicone rubber, sheath is a halogen-free composition with low gas and smoke emission
Armor: no
Number of pairs (bundles) Nominal diameter of conductors, mm
1 – 32 0,4; 0,5; 0,6; 0,8; 1,05; 1,13; 1,38; 1,78
 
Fire safety
  • The National Standards of Ukraine 4809:2007
  • JE-HH FE180/E30…LG, JE-HH FE180/E30… BD - PB 123122288
  • JE-HH FE180/E90… LG, JE-HH FE180/E90… BD - PB 123122588
Detailed description

JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD are communication and signaling cables with copper conductors, insulated with ceramic forming silicone rubber and a sheath of a halogen-free composition with low gas and smoke emission.

Applicability scope

JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD cables are analogous to JE-H(St)H FE180/E30 …LG (BD) and JE-H(St)H FE180/E90 …LG(BD) shielded cables. They are also intended for stationary installation inside premises and buildings and are used to transmit low-power electrical signals in signaling, communication and telecommunication systems, at facilities with increased fire safety requirements, for operation at alternating voltages of up to 300 V.

They are used as a control or connection cable for the data transmission, in industrial control-measuring equipment, office devices, fire alarm systems and intercom systems.

Due to the special design, the cables do not spread combustion and have a low level of smoke emission, and the absence of halogens and, accordingly, low toxic combustion products, allow the use of cables of this brand in social institutions: schools, hospitals, shopping and entertainment complexes, the subway, as well as in residential buildings. In the event of a fire, such cables ensure the operability of the equipment for a certain period of time and allow a complete evacuation of people.

Cables marked E30: JE-HH FE180/E30 …LG (BD) remain operational under fire for 30 minutes, and products marked E90: JE-HH FE180/E90 …LG (BD) can function 90 minutes in case of fire.

Design

The JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD are designed using round copper single-wire conductors. Insulated conductors are twisted together. The LG marking indicates a pair type of stranding of conductors, and the letters BD indicate bundled cables. The number of pairs (bundles) varies from 1 to 32, and the diameter of the conductors is from 0.4 to 1.78 mm.

Insulation of JE-HH FE180/E30 …LG (BD), JE-HH FE180/E90 …LG (BD) is made of ceramic-forming silicone rubber, which emits a minimum amount of substances harmful to humans when exposed to fire. The cable sheath is made of a halogen-free composition, which ensures a significant reduction in the level of gas and smoke emission and the safety of cables for the environment.

You can get more detailed information on the design of cables from the experts of the sales department of EUROPAN LLC.

Operation

JE-HH FE180/E30 …LG, JE-HH FE180/E90 …LG, JE-HH FE180/E30 …BD, JE-HH FE180/E90 …BD cables are designed for operation at ambient temperatures from -30°C to +50°С and maximum air humidity 98% at temperatures of up to +35°С.

Laying without preheating is allowed at a temperature not lower than -15°C.

The minimum bending radius during installation must be at least 15 outer diameters.

The service life of the cables is 15 years. The guaranteed service life is 6 months.

 The website of EUROPAN LLC presents a wide selection of cables and wires for various purposes. Cables for connecting solar panels, communication and signaling, telephone wires and wire radio broadcasting, fire-resistant, low-smoke and non-toxic halogen-free cables – this is not a complete list of products presented on our website. All our products are certified and meet the highest quality standards. You can select and order a cable of the required label size at wholesale prices and with fast delivery to any corner of Ukraine and the CIS country on the website or by phone.

Read more
Nomenclature and weight-dimensional characteristics

Select rated voltage, kV

Number of pairs and nominal diameter of conductors, mm

Nominal outer diameter, mm

Estimated weight of 1 km of cable, kg

1х2х0,4

4,8

28

2х2х0,4

6,6

45

3х2х0,4

7,0

54

4х2х0,4

7,6

65

5х2х0,4

8,2

76

6х2х0,4

8,9

87

8х2х0,4

9,6

105

10х2х0,4

11,4

135

12х2х0,4

11,8

152

16х2х0,4

13,0

189

20х2х0,4

14,6

234

24х2х0,4

16,2

274

30х2х0,4

17,2

325

32х2х0,4

17,8

344

1х2х0,5

5,0

30

2х2х0,5

7,0

50

3х2х0,5

7,3

62

4х2х0,5

8,0

74

5х2х0,5

8,7

87

6х2х0,5

9,4

101

8х2х0,5

10,4

128

10х2х0,5

12,1

157

12х2х0,5

12,5

178

16х2х0,5

13,8

223

20х2х0,5

15,5

276

24х2х0,5

17,2

325

30х2х0,5

18,2

387

32х2х0,5

19,1

420

1х2х0,6

5,6

37

2х2х0,6

8,0

63

3х2х0,6

8,4

79

4х2х0,6

9,2

96

5х2х0,6

10,0

114

6х2х0,6

11,1

137

8х2х0,6

12,0

169

10х2х0,6

14,1

207

12х2х0,6

14,7

244

16х2х0,6

16,3

306

20х2х0,6

18,1

370

24х2х0,6

20,4

446

30х2х0,6

21,6

533

32х2х0,6

22,4

566

1х2х0,8

6,2

48

2х2х0,8

8,8

82

3х2х0,8

9,3

103

4х2х0,8

10,2

127

5х2х0,8

11,1

151

6х2х0,8

12,5

188

8х2х0,8

13,5

232

10х2х0,8

15,8

284

12х2х0,8

16,3

325

16х2х0,8

18,3

420

20х2х0,8

20,2

509

24х2х0,8

22,5

599

30х2х0,8

23,9

720

32х2х0,8

24,8

764

1х2х1,05

7,1

63

2х2х1,05

10,3

112

3х2х1,05

10,9

145

4х2х1,05

11,9

180

5х2х1,05

13,1

216

6х2х1,05

14,7

267

8х2х1,05

15,9

333

10х2х1,05

18,7

411

12х2х1,05

19,3

473

16х2х1,05

21,5

605

20х2х1,05

23,9

738

24х2х1,05

27,0

887

30х2х1,05

28,6

1074

32х2х1,05

29,8

1141

1х2х1,13

7,3

67

2х2х1,13

10,5

120

3х2х1,13

11,2

155

4х2х1,13

12,2

194

5х2х1,13

13,8

247

6х2х1,13

15,1

288

8х2х1,13

16,3

361

10х2х1,13

19,2

446

12х2х1,13

19,9

514

16х2х1,13

22,1

659

20х2х1,13

24,8

817

24х2х1,13

27,7

968

30х2х1,13

29,4

1173

32х2х1,13

30,8

1263

1х2х1,38

8,0

85

2х2х1,38

11,6

152

3х2х1,38

12,2

200

4х2х1,38

13,4

250

5х2х1,38

14,8

302

6х2х1,38

16,5

371

8х2х1,38

17,9

467

10х2х1,38

21,1

577

12х2х1,38

21,8

668

16х2х1,38

24,3

859

20х2х1,38

27,0

1052

24х2х1,38

30,4

1264

30х2х1,38

32,3

1537

32х2х1,38

33,6

1634

1х2х1,78

9,2

116

2х2х1,78

13,5

214

3х2х1,78

14,4

287

4х2х1,78

16,2

380

5х2х1,78

17,8

460

6х2х1,78

19,5

540

8х2х1,78

21,1

687

10х2х1,78

25,0

851

12х2х1,78

25,9

992

16х2х1,78

29,1

1300

20х2х1,78

32,4

1597

24х2х1,78

36,5

1917

30х2х1,78

38,8

2342

32х2х1,78

40,4

2490

Select rated voltage, kV

Number of pairs and nominal diameter of conductors, mm

Nominal outer diameter, mm

Estimated weight of 1 km of cable, kg

1х2х0,4

4,8

28

2х2х0,4

6,6

45

3х2х0,4

7,0

54

4х2х0,4

7,6

65

5х2х0,4

8,2

76

6х2х0,4

8,9

88

8х2х0,4

9,6

106

10х2х0,4

11,4

136

12х2х0,4

11,8

153

16х2х0,4

13,0

191

20х2х0,4

14,6

236

24х2х0,4

16,2

277

30х2х0,4

17,2

328

32х2х0,4

17,8

347

1х2х0,5

5,0

31

2х2х0,5

7,0

51

3х2х0,5

7,3

62

4х2х0,5

8,0

75

5х2х0,5

8,7

88

6х2х0,5

9,4

101

8х2х0,5

10,4

129

10х2х0,5

12,1

158

12х2х0,5

12,5

179

16х2х0,5

13,8

225

20х2х0,5

15,5

279

24х2х0,5

17,2

327

30х2х0,5

18,2

390

32х2х0,5

19,1

424

1х2х0,6

5,6

38

2х2х0,6

8,0

64

3х2х0,6

8,4

79

4х2х0,6

9,2

97

5х2х0,6

10,0

115

6х2х0,6

11,1

138

8х2х0,6

12,0

170

10х2х0,6

14,1

209

12х2х0,6

14,7

246

16х2х0,6

16,3

309

20х2х0,6

18,1

374

24х2х0,6

20,4

451

30х2х0,6

21,6

539

32х2х0,6

22,4

571

1х2х0,8

6,2

48

2х2х0,8

8,8

82

3х2х0,8

9,3

104

4х2х0,8

10,2

128

5х2х0,8

11,1

152

6х2х0,8

12,5

189

8х2х0,8

13,5

233

10х2х0,8

15,8

286

12х2х0,8

16,3

327

16х2х0,8

18,3

424

20х2х0,8

20,2

513

24х2х0,8

22,5

604

30х2х0,8

23,9

726

32х2х0,8

24,8

771

1х2х1,05

7,1

64

2х2х1,05

10,3

113

3х2х1,05

10,9

145

4х2х1,05

11,9

181

5х2х1,05

13,1

217

6х2х1,05

14,7

269

8х2х1,05

15,9

336

10х2х1,05

18,7

414

12х2х1,05

19,3

477

16х2х1,05

21,5

609

20х2х1,05

23,9

744

24х2х1,05

27,0

894

30х2х1,05

28,6

1083

32х2х1,05

29,8

1150

1х2х1,13

7,3

68

2х2х1,13

10,5

120

3х2х1,13

11,2

156

4х2х1,13

12,2

195

5х2х1,13

13,8

249

6х2х1,13

15,1

290

8х2х1,13

16,3

364

10х2х1,13

19,2

449

12х2х1,13

19,9

518

16х2х1,13

22,1

664

20х2х1,13

24,8

824

24х2х1,13

27,7

975

30х2х1,13

29,4

1183

32х2х1,13

30,8

1273

1х2х1,38

8,0

85

2х2х1,38

11,6

153

3х2х1,38

12,2

201

4х2х1,38

13,4

252

5х2х1,38

14,8

304

6х2х1,38

16,5

373

8х2х1,38

17,9

470

10х2х1,38

21,1

581

12х2х1,38

21,8

673

16х2х1,38

24,3

865

20х2х1,38

27,0

1059

24х2х1,38

30,4

1273

30х2х1,38

32,3

1548

32х2х1,38

33,6

1646

1х2х1,78

9,2

117

2х2х1,78

13,5

215

3х2х1,78

14,4

288

4х2х1,78

16,2

382

5х2х1,78

17,8

462

6х2х1,78

19,5

543

8х2х1,78

21,1

691

10х2х1,78

25,0

856

12х2х1,78

25,9

998

16х2х1,78

29,1

1308

20х2х1,78

32,4

1607

24х2х1,78

36,5

1929

30х2х1,78

38,8

2357

32х2х1,78

40,4

2507

Kiev, 04080, st. Kirillovskaya, 86
info@europan.ua
Expand mapCollapse map
Up