PvBbSHp

The National Standards of Ukraine IEC 60502-1:2009
  • PvBbShp is a power cable with copper conductors, insulation made of cross-linked polyethylene, and a protective cover of the BbSHp type made of steel bands, and a protective hose made of light-stabilized polyethylene.
  • It is designed for the transmission and distribution of electrical energy in stationary installations for a rated alternating voltage of 0.66; 1 kV with a frequency of 50 Hz.
  • It is used for laying in the ground (in trenches) with any corrosiveness of the soil, the leakage currents, regardless of the proximity of groundwater, in rooms, tunnels, channels and partially flooded structures with various corrosive conditions, as well as outdoors, if the cable is not subjected to significant tension strain, but if there is a risk of mechanical damage during operation.
Minimum service life is 30 years
Guaranteed service life is 5 years
Minimum bending radius Single-conductor cable: 10 x outer diameter
Multi-conductor cable: 7.5 x outer diameter
Temperature range installation: not below -15°С
operation: from -50°С to +50°С
Interpretation of cable PvBbSHp

The copper conductor is not defined on the cable marking;

Pv – insulation made of cross-linked polyethylene;

B – armor made of steel galvanized bands;

b – without bedding under armor;

SHp – extruded protective hose made of light-stabilized polyethylene. 

Design
Conductors: copper single-wire or multi-wire of the 1st or 2d flexibility class, of round or sector shape (class 1, 2 DSTU EN 60228)
Insulation: conductor insulation – cross-linked polyethylene, hose-type sheath made of light-stabilized polyethylene
Armor: galvanized steel bands
Rated voltage, kV
0,66 1
Number of conductors Nominal cross-section area of the key conductors, mm2
1 10 — 50 10 — 240
2, 3, 4, 5 2,5 — 50 2,5 — 240
 
Fire safety
  • The National Standards of Ukraine 4809:2007
  • PvBbSHp - PB 1XXXXXXXX
Certifications
Detailed description

PvBbSHp is a power cable with copper conductors, insulation made of cross-linked polyethylene (XLPE) and a BbSHp-type protective sheath. It is designed for the transmission and distribution of electrical energy in stationary installations for a rated alternating voltage of 0.66; 1 kV with a frequency of 50 Hz.

Applicability scope

Armoured cable PvBbSHp is mainly used in conditions where there is a risk of mechanical damage to the cable during laying or operation. It is used most often for installation in the ground, with any corrosiveness of the soil, the leakage currents, regardless of the proximity of the groundwater, save for the heaving and subsidence soils. It can be used for the installation of power lines by air without significant tension strain and also laid along the bottom of non-navigable reservoirs, when buried in the ground. It is also used for laying in rooms, tunnels, channels, partially flooded structures with various corrosive conditions.

The group laying is allowed in outdoor electrical installations and industrial premises using the additional protection against fire.

Design

The conductors of PvBbSHp cable are copper, single-wire or multi-wire, round or sector (class 1, 2 DSTU EN 60228). Conductors insulation is made of cross-linked polyethylene (XLPE) with solid color marking or longitudinal strip marking. The conductors are stranded into a core which may be covered with a sheath of chalk-filled nonvulcanizing rubber compound, and the spaces between the conductors are filled. Multi-conductors cables can have all conductors of the same cross-section or one conductor (neutral or ground) of a smaller cross-section. The protective cover consisting of two galvanized steel tape bands and a protective hose made of light-stabilized polyethylene provide a maximum protection to the cable.

Operation

PvBbSHp is manufactured for operation in areas with a temperate and cold climate and is used in a stationary state at temperatures from -50°C to +50°C. Air humidity during operation should not exceed 98% at temperatures up to +35°С. You may not preheat the cable during installation if the ambient temperature is at least -15°C.

The minimum bend radius during installation should be at least 7.5 outer cable diameters for multi-conductors cables and 10 outer cable diameters for single-conductor cables.

The long-term permissible temperature of heating conductors during operation is 90°C. The maximum permissible temperature at short-circuit currents is 250°C, in an emergency mode no more than 130°C.

The service life of the cable is at least 30 years. The guaranteed service life is 5 years.

The website of EUROPAN LLC presents an armoured cable PvBbSHp of its own production, the high quality of which is confirmed by the certificates of compliance with Ukrainian legislation. You can buy a copper armoured cable PvBbSHp or aluminum APvBbSHp, check prices, get additional information on the technical characteristics of the products you are interested in, by contacting our sales department by phone numbers indicated on the website.

Read more

Permissible short circuit currents of cables

Nominal conductor cross-section, mm²

Permissible current of one-second short circuit of cables, kA

Nominal conductor cross-section, mm²

Permissible current of one-second short circuit of cables, kA

2,5 0,34 50 6,50
4,0 0,54 70 9,38
6,0 0,81 95 13,03
10 1,36 120 16,43
16 2,16 150 20,26
25 3,46 185 25,35
35 4,80 240 33,32

 

Nomenclature and mass-dimensional characteristics

Select rated voltage, kV

Number of conductors and nominal cross-section, mm2

Nominal outer diameter, mm

Estimated weight of 1 km of cables, kg
1 x 10 11,4 251
1 x 16 12,9 342
1 x 25 14,8 472
1 x 35 16,0 586
1 x 50 17,7 756
2 x 2,5 12,6 233
2 x 4,0 13,5 279
2 x 6,0 14,8 346
2 x 10 16,3 451
2 x 16 19,6 636
2 x 25 23,0 886
2 x 35 25,7 1135
2 x 50 29,2 1497
3 x 2,5 13,1 269
3 x 4,0 14,0 331
3 x 6,0 15,4 418
3 x 10 17,1 563
3 x 16 20,6 813
3 x 25 24,4 1168
3 x 35 27,1 1505
3 x 50 31,1 2029
3 x 4,0 + 1 x 2,5 15,1 382
3 x 6,0 + 1 x 4,0 16,4 479
3 x 10 + 1 x 6,0 17,8 630
3 x 16 + 1 x 10 21,6 930
3 x 25 + 1 x 16 25,9 1362
3 x 35 + 1 x 16 27,8 1679
3 x 50 + 1 x 25 32,8 2315
4 x 2,5 13,8 311
4 x 4,0 15,1 396
4 x 6,0 16,4 499
4 x 10 18,3 677
4 x 16 22,2 1004
4 x 25 26,7 1469
4 x 35 29,4 1896
4 x 50 34,5 2607
5 x 2,5 14,9 365
5 x 4,0 16,1 461
5 x 6,0 17,5 588
5 x 10 19,9 817
5 x 16 24,3 1221
5 x 25 29,0 1791
5 x 35 32,3 2337
5 x 50 37,9 3222

Number of conductors and nominal cross-section, mm2

Nominal outer diameter, mm

Estimated weight of 1 km of cables, kg
1 x 10 11,6 256
1 x 16 13,1 348
1 x 25 15,0 479
1 x 35 16,2 593
1 x 50 17,9 763
1 x 70 19,0 962
1 x 95 20,9 1244
1 x 120 22,5 1498
1 x 150 24,6 1818
1 x 185 27,0 2231
1 x 240 29,5 2802
2 x 2,5 13,0 243
2 x 4,0 13,9 290
2 x 6,0 15,2 356
2 x 10 16,7 462
2 x 16 20,0 648
2 x 25 23,6 907
2 x 35 26,1 1149
2 x 50 29,6 1513
2 x 70 32,0 1931
2 x 95 36,2 2538
2 x 120 39,4 3060
2 x 150 43,4 3720
2 x 185 48,5 4610
2 x 240 53,7 5806
3 x 2,5 13,5 280
3 x 4,0 14,7 349
3 x 6,0 15,8 430
3 x 10 17,5 576
3 x 16 21,0 828
3 x 25 25,1 1194
3 x 35 27,5 1523
3 x 50 31,5 2049
3 x 70 34,4 2674
3 x 95 38,3 3499
3 x 120 41,9 4268
3 x 150 46,6 5244
3 x 185 51,4 6466
3 x 240 57,6 8255
3 x 4,0 + 1 x 2,5 15,6 396
3 x 6,0 + 1 x 4,0 16,9 494
3 x 10 + 1 x 6,0 18,8 655
3 x 16 + 1 x 10 22,1 947
3 x 25 + 1 x 16 26,4 1381
3 x 35 + 1 x 16 28,3 1699
3 x 50 + 1 x 25 33,3 2338
3 x 70 + 1 x 35 36,5 3075
3 x 95 + 1 x 50 40,5 4039
3 x 120 + 1 x 70 45,0 5038
3 x 150 + 1 x 70 49,5 5998
3 x 185 + 1 x 95 54,7 7474
3 x 240 + 1 x 120 61,3 9506
4 x 2,5 14,5 331
4 x 4,0 15,6 410
4 x 6,0 16,9 513
4 x 10 18,8 692
4 x 16 22,7 1022
4 x 25 27,2 1490
4 x 35 30,1 1930
4 x 50 35,0 2633
4 x 70 37,8 3428
4 x 95 42,1 4510
4 x 120 46,5 5544
4 x 150 51,3 6788
4 x 185 57,3 8447
4 x 240 63,7 10757
5 x 2,5 15,4 381
5 x 4,0 16,7 478
5 x 6,0 18,1 598
5 x 10 20,4 836
5 x 16 25,0 1254
5 x 25 29,6 1817
5 x 35 32,8 2365
5 x 50 38,4 3254
5 x 70 41,5 4250
5 x 95 46,9 5651
5 x 120 51,2 6900
5 x 150 57,1 8519
5 x 185 63,3 10564
5 x 240 70,5 13468
Kiev, 04080, st. Kirillovskaya, 86
info@europan.ua
Expand mapCollapse map