KVVGE, KVVGEng, KVVGEngd

TU U 27.3-39543889-005:2019, The National Standards of Ukraine HD 627 S1:2012
  • KVVGE, KVVGEng, KVVGEngd are control cables with copper conductors, PVC compound insulation, mutual protective shield and PVC sheath.
  • They are designed for fixed connection to electrical devices, apparatuses, terminal block jumpers of electrical switchgears with a rated alternating voltage up to 660 V, with a frequency up to 100 Hz or a constant voltage up to 1000 V.
  • They are used for laying in rooms, channels, tunnels without mechanical stress on the cable in an aggressive environment and when there is a need to protect electrical circuits from the influence of external electric fields. They can be laid outdoors, provided they are protected from mechanical damage and exposure to direct sunlight.
Minimum service life is - 20 years when laid in the ground (in trenches) and on overpasses, provided the cables are protected from ultraviolet radiation;
- 25 years when laying in rooms, tunnels, channels
Guaranteed service life is 3 years
Minimum bending radius when laying at ambient temperature not lower than 0°С, not less than:
- 3 x outer diameter - for cables with an outer diameter up to 10 mm inclusive;
- 4 x outer diameter - for cables with an outer diameter over 10 to 25 mm inclusive;
- 6 x outer diameter - for cables with an outer diameter over 25 mm
Temperature range installation: not below -15°С
operation: -50°С to +50°С
Interpretation of cables KVVGE, KVVGEng, KVVGEngd

The copper conductor is not indicated on the cable marking;

K – control cable;

V – PVC insulation;

V – PVC sheath;

G – without armor;

E – shielded;

«ng» – does not support combustion;

«ngd» – does not support combustion, with reduced smoke and gas emission.

Design
Conductors: copper single-wire (class 1 DSTU EN 60228)
Insulation: PVC compound
Armor: no
Number of conductors Nominal cross-section area of the key conductors, mm2
2, 3, 4, 5, 7, 10, 14, 19, 27, 37 0,75; 1,0; 1,5; 2,5
4, 5, 7, 10, 14, 19 4,0; 6,0; 10
 
Fire safety
  • The National Standards of Ukraine 4809:2007
  • KVVGE - PB 1XXXXXXXX
  • KVVGEng - PB 12XXXXXXX
  • KVVGEngd - PB 122111XXX
Certifications
Detailed description

KVVGE, KVVGEng, KVVGEngd are control cables with copper conductors, PVC compound insulation, mutual protective shield and PVC sheath. They are designed for fixed connection to electrical devices, apparatuses, terminal block jumpers of electrical switchgear with a rated alternating voltage up to 660 V, with a frequency up to 100 Hz or a constant voltage up to 1000 V.

Applicability scope

The control cables are usually used to build control and management lines, relay protection, signaling, blocking networks, remote control, as well as to connect electrical appliances and devices to other control devices. They are used to control the state, position and mode of operation of objects, access to which is difficult or impossible.

KVVGE is used for laying in rooms, channels, tunnels provided there is no mechanical stress on the cable in an aggressive environment and when there is a need to protect electrical circuits from the influence of external electric fields. Installation outdoors is allowed, provided that it is protected from mechanical damage and exposure to direct sunlight.

KVVGE cables made with the use of non-combustible insulating materials are used n places of increased fire hazard, where special fire-prevention measures are required, as well as for laying in bundles. Such cables are marked with indices «ng» and «ngd». KVVGEng is a cable that does not support combustion, and KVVGEngd does not support combustion with a low level of smoke and gas emission during a fire.

Design

The design of KVVGE is based on the single-wire copper conductors of the 1st flexibility class (class 1 of DSTU EN 60228). The conductors are covered with an insulating layer of PVC compound. They have distinctive color or digital markings. The inner and outer sheaths of the cable are also made of PVC compound. And the shield is made of copper or aluminum foil. A separating layer of cable paper or plastic tape can be used to separate the conductors from the outer insulation.

Operation

The operating temperature of KVVGE, KVVGEng, KVVGEngd ranges from -50°C to +50°C. The permissible air humidity is not higher than 98% at a temperature of +35°С. Installation without preheating is possible at temperatures not lower than -15°C.

The bend radius of cables when laying at ambient temperature not lower than 0°С is not less than:

– 3 cable diameters – for cables with an outer diameter up to 10 mm inclusive;

– 4 cable diameters – for cables with an outer diameter over 10 to 25 mm inclusive;

– 6 cable diameters – for cables with an outer diameter over 25 mm.

Long-term permissible conductors heating temperature during operation is +70°С.

The service life of the cables is as follow:

  • at least 20 years – when laying in earth trenches and on overpasses, provided they are protected from direct sunlight;
  • 25 years – when laid in rooms, channels and tunnels.

The guaranteed service life is 3 years.

The website of EUROPAN LLC presents control cables KVVGE and AKVVGE, certified in accordance with the legislation of Ukraine. When ordering a cable from EUROPAN LLC, you can be sure regarding the quality of products, high level of service and favorable prices. Our managers will advise you on technical characteristics, order terms and help you to choose the right product.

Read more
 
Nomenclature and mass-dimensional characteristics

Select rated voltage, kV

Number of conductors and nominal cross-section, mm2

Nominal outer diameter, mm

Estimated weight of 1 km of cables, kg
2 x 0,75 7,1 63
3 x 0,75 7,5 76
4 x 0,75 8,0 91
5 x 0,75 9,3 121
7 x 0,75 9,9 146
10 x 0,75 12,1 197
14 x 0,75 13,0 248
19 x 0,75 14,2 313
27 x 0,75 16,7 421
37 x 0,75 19,0 562
2 x 1,0 7,5 71
3 x 1,0 7,8 87
4 x 1,0 9,0 117
5 x 1,0 9,7 140
7 x 1,0 10,4 170
10 x 1,0 12,7 231
14 x 1,0 13,7 293
19 x 1,0 15,0 373
27 x 1,0 17,7 505
37 x 1,0 20,1 677
2 x 1,5 8,0 85
3 x 1,5 8,3 106
4 x 1,5 9,6 143
5 x 1,5 10,4 172
7 x 1,5 11,1 212
10 x 1,5 13,7 290
14 x 1,5 14,8 375
19 x 1,5 16,3 482
27 x 1,5 19,7 675
37 x 1,5 21,9 884
2 x 2,5 9,4 123
3 x 2,5 9,8 156
4 x 2,5 10,6 191
5 x 2,5 11,4 233
7 x 2,5 12,3 293
10 x 2,5 15,3 405
14 x 2,5 16,5 531
19 x 2,5 18,7 708
27 x 2,5 22,1 971
37 x 2,5 25,1 1307
4 x 4,0 12,2 269
5 x 4,0 13,2 330
7 x 4,0 14,3 422
10 x 4,0 18,0 587
14 x 4,0 19,8 798
19 x 4,0 22,0 1042
4 x 6,0 13,4 360
5 x 6,0 14,6 445
7 x 6,0 15,9 576
10 x 6,0 20,4 826
14 x 6,0 22,1 1102
19 x 6,0 25,0 1474
4 x 10 16,3 555
5 x 10 17,8 692
7 x 10 19,8 923
10 x 10 25,6 1320
14 x 10 27,8 1773
19 x 10 30,9 2344

Select rated voltage, kV

Number of conductors and nominal cross-section, mm2

Nominal outer diameter, mm

Estimated weight of 1 km of cables, kg
2 x 0,75 7,1 64
3 x 0,75 7,5 78
4 x 0,75 8,0 93
5 x 0,75 9,3 124
7 x 0,75 9,9 149
10 x 0,75 12,1 200
14 x 0,75 13,0 252
19 x 0,75 14,2 317
27 x 0,75 16,7 426
37 x 0,75 19,0 569
2 x 1,0 7,5 72
3 x 1,0 7,8 89
4 x 1,0 9,0 120
5 x 1,0 9,7 142
7 x 1,0 10,4 173
10 x 1,0 12,7 234
14 x 1,0 13,7 297
19 x 1,0 15,0 378
27 x 1,0 17,7 511
37 x 1,0 20,1 684
2 x 1,5 8,0 86
3 x 1,5 8,3 108
4 x 1,5 9,6 146
5 x 1,5 10,4 175
7 x 1,5 11,1 215
10 x 1,5 13,7 295
14 x 1,5 14,8 379
19 x 1,5 16,3 487
27 x 1,5 19,7 682
37 x 1,5 21,9 892
2 x 2,5 9,4 126
3 x 2,5 9,8 159
4 x 2,5 10,6 194
5 x 2,5 11,4 236
7 x 2,5 12,3 297
10 x 2,5 15,3 410
14 x 2,5 16,5 536
19 x 2,5 18,7 714
27 x 2,5 22,1 979
37 x 2,5 25,1 1317
4 x 4,0 12,2 272
5 x 4,0 13,2 334
7 x 4,0 14,3 426
10 x 4,0 18,0 593
14 x 4,0 19,8 805
19 x 4,0 22,0 1050
4 x 6,0 13,4 364
5 x 6,0 14,6 450
7 x 6,0 15,9 581
10 x 6,0 20,4 833
14 x 6,0 22,1 1110
19 x 6,0 25,0 1484
4 x 10 16,3 560
5 x 10 17,8 697
7 x 10 19,8 930
10 x 10 25,6 1330
14 x 10 27,8 1784
19 x 10 30,9 2357

Select rated voltage, kV

Number of conductors and nominal cross-section, mm2

Nominal outer diameter, mm

Estimated weight of 1 km of cables, kg
2 x 0,75 7,1 68
3 x 0,75 7,5 82
4 x 0,75 8,0 98
5 x 0,75 9,3 132
7 x 0,75 9,9 158
10 x 0,75 12,1 213
14 x 0,75 13,0 267
19 x 0,75 14,2 336
27 x 0,75 16,7 451
37 x 0,75 19,0 603
2 x 1,0 7,5 77
3 x 1,0 7,8 94
4 x 1,0 9,0 127
5 x 1,0 9,7 151
7 x 1,0 10,4 183
10 x 1,0 12,7 248
14 x 1,0 13,7 314
19 x 1,0 15,0 399
27 x 1,0 17,7 538
37 x 1,0 20,1 721
2 x 1,5 8,0 91
3 x 1,5 8,3 114
4 x 1,5 9,6 153
5 x 1,5 10,4 184
7 x 1,5 11,1 226
10 x 1,5 13,7 310
14 x 1,5 14,8 398
19 x 1,5 16,3 510
27 x 1,5 19,7 715
37 x 1,5 21,9 934
2 x 2,5 9,4 132
3 x 2,5 9,8 166
4 x 2,5 10,6 203
5 x 2,5 11,4 247
7 x 2,5 12,3 310
10 x 2,5 15,3 427
14 x 2,5 16,5 558
19 x 2,5 18,7 743
27 x 2,5 22,1 1017
37 x 2,5 25,1 1368
4 x 4,0 12,2 284
5 x 4,0 13,2 349
7 x 4,0 14,3 443
10 x 4,0 18,0 616
14 x 4,0 19,8 835
19 x 4,0 22,0 1089
4 x 6,0 13,4 378
5 x 6,0 14,6 467
7 x 6,0 15,9 601
10 x 6,0 20,4 861
14 x 6,0 22,1 1145
19 x 6,0 25,0 1531
4 x 10 16,3 579
5 x 10 17,8 722
7 x 10 19,8 960
10 x 10 25,6 1374
14 x 10 27,8 1840
19 x 10 30,9 2427