Operation<\/strong><\/h5>\nThe operating temperature of KGNV-M is in the range from -40\u00b0\u0421 to +50\u00b0\u0421. The installation without preheating is carried out at a temperature not lower than -15\u00b0C.<\/p>\n
The installation and operating radius of the bend of the cable line must be at least 8 cable diameters, and the temperature of long-term heating must be +70\u00b0\u0421.<\/p>\n
Tensile forces on the cable should be no more than 19.6 N (2.0 kgf) per 1 mm2 <\/sup>of the total cross-section of all conductors.<\/p>\nKGNV-M, KGNV-Mng, KGNV-Mngd must be resistant to multiple bends at an angle of \u00b1 \u03c0\/2 rad with a nominal tensile force of 49 N (5.0 kgf).<\/p>\n
The service life of cables, provided the rules of operation are complied, is at least 4 years, but is not limited to it, and depends on the technical condition of the cable. The guaranteed service life is 6 months from the date of putting the cable into operation, but not later than 12 months from the date of manufacture.<\/p>\n
On the website of EUROPAN Cable Plant, you can select and buy at wholesale prices KGNV-M cables and other high-quality products certified in accordance with the legislation of Ukraine. Here you can also familiarize yourself with the assortment, terms of order and delivery. And by contacting the sales department, you will receive advice on all issues related to the product, assistance in the selection of a conductor, taking into account your needs, and individual support at all stages of purchase. <\/p>\n<\/div>
Read more<\/span> <\/i><\/div>\n","protected":false},"excerpt":{"rendered":"KGNV-M is a kind of KGNV cable. By design, they are very similar, and the main difference lies in the field of their operation. So, KGNV is used as a power cable, and KGNV-M is used as a control cable. The latter is also capable of transmitting electric current, but it is mainly used to control the operation of equipment in hard-to-reach places.
\nKGNV-M, KGNV-Mng, KGNV-Mngd are flexible multi-conductors cables with a copper conductor, the PVC insulation and the sheath. They are designed for connection of mobile mechanisms to electrical networks for a rated alternating voltage of 600 V with a frequency of up to 400 Hz or a constant rated voltage of 1000 V.
\nApplicability scope
\nKGNV-M is used to connect mobile mechanisms and equipment to the power grid, as well as to transmit data about their condition in conditions requiring flexible connections. This cable is used is various industries.
\nKGNV-M is resistant to numerous bends resulting from frequent cable movements and can be used for moving devices and portable power tools. It is resistant to lubricating oils, gasoline, diesel and solar radiation, making it suitable for outdoor use. It also does not support combustion in case of a single laying.<\/p>\n","protected":false},"author":1,"featured_media":7651,"parent":4800,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"template-page-product.php","meta":{"inline_featured_image":false},"yoast_head":"\n