{"id":11096,"date":"2023-10-27T15:16:02","date_gmt":"2023-10-27T12:16:02","guid":{"rendered":"https:\/\/europan.ua\/?page_id=11096"},"modified":"2023-10-30T15:28:45","modified_gmt":"2023-10-30T12:28:45","slug":"ydyp","status":"publish","type":"page","link":"https:\/\/europan.ua\/en\/produkciya\/ce-certified-cables\/power-cables\/ydyp\/","title":{"rendered":"YDYp"},"content":{"rendered":"
YDYp <\/span>is a type of cable YDY\u00a0but with flat design. A specific feature of this brand is the parallel laying of conductors in one plane, that determined the scope of its use.<\/p>\n YDYp is suitable for laying under plaster, laminate, concrete layer, in gypsum plasterboard recesses, in skirting wiring ducts, pipes and cable trays, for installation of hidden wiring and in places where space saving is important. It is used for laying wiring in apartments and offices, industrial premises, in dry channels and tunnels, on special cable trays, in blocks. It can be used for installation in an aggressive environment and outdoors with the use of protection against mechanical damage. The design of YDYp is based on copper single-wire conductors of the 1st flexibility class (class 1 of DSTU EN 60228). The use of solid conductors allows this cable to be laid only for stationary conditions without permanent bends. The number of conductors is 2 or 3 with a cross section from 1.5 to 10 mm2<\/sup>. The conductors are insulated with PVC compound and laid in one plane. There is a polyvinyl chloride sheath over the conductors. The insulation of conductors usually has solid color marking, less often one may meet longitudinal stripe marking. The insulation of the neutral conductor is blue, and the ground conductor is yellow-green. The cross-section of the conductors is usually the same, although in three-conductor cables the grounding conductor may be smaller.<\/p>\n The operating temperature of the cable is from -50\u00b0C to +50\u00b0C. And with a relative humidity of up to 98% and a temperature not higher than +35\u00b0C. The laying of the cable without preheating is permissible at a temperature not lower than -15\u00b0C.<\/p>\n The minimum bend radius during installation must be at least 10 outer cable diameters. Long-term permissible conductor heating temperature during operation should not exceed 70\u00b0C. At short-circuit currents, the cable can withstand 160\u00b0C, and in an overload mode – 80\u00b0C.<\/p>\n The service life of YDYp reaches 30 years. The guaranteed service life is 5 years.<\/p>\n\u00a0<\/strong>Applicability scope<\/strong><\/h5>\n
\u00a0<\/strong>Design<\/strong><\/h5>\n
Operation<\/strong><\/h5>\n