{"id":11087,"date":"2023-10-27T14:32:08","date_gmt":"2023-10-27T11:32:08","guid":{"rendered":"https:\/\/europan.ua\/?page_id=11087"},"modified":"2023-11-06T11:59:15","modified_gmt":"2023-11-06T08:59:15","slug":"n2xch","status":"publish","type":"page","link":"https:\/\/europan.ua\/en\/produkciya\/ce-certified-cables\/power-cables\/n2xch\/","title":{"rendered":"N2XCH"},"content":{"rendered":"
N2XCH<\/strong><\/span>\u00a0is a power cable with copper conductors, vulcanized (cross-linked) polyethylene insulation, PVC compound sheath. It is designed for the transmission and distribution of the electrical energy in stationary installations for an alternating voltage of 0.66; 1 kV with a frequency of 50 Hz.<\/p>\n This brand is designed for cable structures, production and storage facilities, specialized cable tray systems, channels, cable cellars, mines and collectors. The cable is more often used for indoor wiring, although outdoor installation is also possible, provided there is no risk of mechanical damage. N2XCH is convenient for the installation and has good tensile strength characteristics, which allows it to be used on bridges and multi-level routes. It is resistant to moisture and can be used in rooms with high humidity.<\/p>\n It is not recommended for laying in the ground while in earth trenches it is necessary to use protection against mechanical damage.<\/p>\n N2XCH does not spread combustion in case of a single laying. The cables in a sheath with non-combustible properties are used in crowded rooms with increased requirements for fire safety, places with a particularly high risk of fire, as well as in dry environments. They are marked with the letter index \u00abng\u00bb which means that the cable has a reduced flammability. And the index \u00abngd\u00bb indicates that the cable is flame-retardant and practically does not emit smoke during smoldering and burning. N2XCH are used for group laying, since they practically do not support combustion in one bundle with other cables. N2XCH use a copper conductors. The conductors can be single-wire or multi-wire, of the 1st or 2d flexibility classes (class 1, 2 DSTU EN 60228). The number of conductors varies from 1 to 5. Their insulation is made of cross-linked (vulcanized) polyethylene. In multi-conductors cables, the conductors are stranded into a core and are color-coded. The outer sheath of the cable is made of PVC compound.<\/p>\n The experts of EUROPAN LLC will give you more detailed information on the characteristics of the cable, help you to select the conductor, taking into account the load power and the temperature range, as well as provide you with an additional advice.<\/p>\n The normal cable operation is possible in a stationary state at temperatures from -50\u00b0C to + 50\u00b0C. The PVC material is thermoplastic and hardens at low temperatures, therefore installation is permissible at temperatures not lower than -15\u00b0C, otherwise the cable must be preheated.<\/p>\n The maximum permissible air humidity at which the cable is sufficient reaches 98% at a temperature\u00a0of +35\u00b0\u0421. The bend radius during installation is 7.5 and 10 outer cable diameters for multi-conductors and single-conductor cables, respectively.<\/p>\nApplicability scope<\/strong><\/h5>\n
Design<\/strong><\/h5>\n
\u00a0<\/strong>Operation<\/strong><\/h5>\n